Quality Control,
Precision Assured

ASTRA is the intelligent QC management platform for clinical microbiology laboratories. Automate Westgard rule detection, track trends with Levey-Jennings charts, and maintain audit-ready compliance — all in one system.

astra-qc.co.uk
ASTRA QC Management
Dashboard
Enter Results
Trends
QC Alerts
248
Results Entered
241
Within Range
7
Out of Range
97.2%
Compliance
OrganismPassFailStatus
E. coli ATCC 2592246197.9%
S. aureus ATCC 29213480100%
P. aeruginosa ATCC 2785344295.7%
Everything Your Lab Needs

ASTRA replaces spreadsheets and manual QC processes with a purpose-built platform designed for the precision demands of clinical microbiology.

📊

Real-Time Dashboard

Compliance rates, pass/fail counts, and organism-level summaries at a glance. Filter by time period for focused analysis.

📈

Levey-Jennings Charts

Interactive trend charts with control limits, mean lines, and Westgard violation markers. Track by antibiotic across all organisms.

🔔

Westgard Rule Alerts

Automatic detection of 1-3s, 2-2s, 4-1s, and 10x rule violations with filterable alerts and corrective action workflows.

📝

Weekly Results Entry

Zone diameters and MIC values with lot tracking, expiry flagging, inline pass/fail colour feedback, and partial save support.

🔒

Role-Based Access

Admin and User roles with PIN-controlled access to organism configuration, user management, and system settings.

📋

Full Audit Trail

Every login, data save, corrective action, and settings change logged with timestamp, user, and detail — audit-ready at all times.

⚙️

EUCAST Auto-Setup

Select a QC organism and ASTRA pulls in every applicable antibiotic, disc content, and reference range directly from the EUCAST QC tables. No manual entry.

📧

Email Notifications

Automated alerts to configured recipients when corrective actions are raised. Keep your team informed without manual follow-up.

🌙

Dark Mode

Full dark theme for comfortable use in low-light environments. Every screen, chart, and input adapts seamlessly.

Your QC Status
at a Glance

Compliance metrics, organism-level breakdowns, and time-filtered views give lab managers the full picture without digging through data.

  • Results Entered, Within Range, Out of Range, and Compliance Rate
  • Filter by Last Week, Last Month, or All Time
  • Organism table with per-row status badges
  • Click any organism to jump straight to data entry
astra-qc.co.uk — Dashboard
186
Results Entered
180
Within Range
6
Out of Range
96.8%
Compliance
OrganismTestedPassFailRate
E. coli ATCC 259223635197.2%
S. aureus ATCC 2921330300100%
P. aeruginosa 278532422291.7%
E. faecalis ATCC 2921218180100%
Wednesday Morning,
Sorted in Minutes

The weekly data entry workflow mirrors real lab practice. Select your organism, enter zone diameters, and ASTRA tells you instantly what's in range and what isn't.

  • Inline colour feedback — green for pass, red for fail, as you type
  • Lot numbers and expiry dates tracked per antibiotic
  • Expired lots are flagged automatically
  • Partial saves supported — come back and finish later
  • Out-of-range results trigger a corrective action prompt on save
astra-qc.co.uk — Enter Results
E. coli ATCC 25922
Mueller-Hinton · 35°C 18±2h
Week 12
Antibiotic Range Zone Status
Ampicillin 1016–2219PASS
Ciprofloxacin 530–4035PASS
Gentamicin 1019–2628FAIL
Piperacillin-Taz. 3621–2724PASS
Lot: AB-2026-0412 · Exp: 2026-09-30
Save
Catch Problems
Before They Escalate

Westgard rule violations are detected automatically and presented with intelligent filtering. Raise corrective actions directly from the alert, and track resolution.

  • 1-3s, 2-2s, 4-1s, and 10x rule detection
  • Filter by organism, antibiotic, date range, or lot number
  • Rule summary tiles with violation counts
  • Corrective action modal with email notification on save
astra-qc.co.uk — QC Alerts
1-3s
3
2-2s
1
4-1s
0
10x
0
1-3sE. coli 25922
Ampicillin 10 · Wk 14
1-3sP. aeruginosa 27853
Gentamicin 10 · Wk 12
2-2sS. aureus 29213
Cefoxitin 30 · Wk 10–11
1-3sE. coli 25922
Ciprofloxacin 5 · Wk 8
New EUCAST Version?
One Click.

When EUCAST publishes updated QC tables, ASTRA lets you switch versions instantly. Ranges, targets, and available antibiotics update across your entire configuration — with zero manual data entry.

  • Switch between EUCAST QC table versions in a single click
  • Updated ranges apply to current and future data only — historical records are preserved exactly as entered
  • Add a new organism by selecting from the EUCAST QC table — all applicable antibiotics, disc contents, and reference ranges are pulled in automatically
  • Choose exactly which antibiotics your lab tests — no unnecessary clutter
  • Need a non-standard organism? Add custom strains with manually defined ranges
astra-qc.co.uk — Settings
EUCAST QC Table Version
v14.0
2024
v15.0
2025
v16.0
2026
● Active
Add Organism
QC Organism
E. coli ATCC 25922
Available Antibiotics (auto-populated)
AntibioticDiscRange
Ampicillin1016–22
Ciprofloxacin530–40
Gentamicin1019–26
Piperacillin-Tazobactam3621–27
From Setup to QC in Minutes

ASTRA is designed for fast deployment. Configure your organisms, start entering data, and let the system handle the analysis.

1

Configure

Set your EUCAST QC table version, select your organisms, and tick the antibiotics you test. Ranges are pulled in automatically — no manual setup.

2

Record

Enter weekly zone diameters and MIC values. Lot numbers, expiry dates, and reader details are captured alongside.

3

Analyse

Westgard rules run automatically. Levey-Jennings charts reveal trends. Violations surface in the alerts dashboard.

4

Act

Raise corrective actions from any violation. Email notifications keep the team informed. The audit log records everything.

Audit-Ready by Design

Built for regulated environments. Every interaction is logged, every data point is traceable, and historical records are preserved indefinitely.

Corrective Actions

When a result falls outside the acceptable range, ASTRA prompts for a corrective action before the data can be saved. Every out-of-range result is recorded alongside the action taken, who recorded it, and when — giving you a complete history ready for any assessor.

  • Out-of-range results trigger a mandatory corrective action prompt
  • All corrective actions stored with organism, antibiotic, zone value, and date
  • Email notification sent to configured recipients on save
  • Dedicated Corrective Actions page with full searchable history
astra-qc.co.uk — Corrective Actions
Corrective Actions
OOR E. coli 25922 · Gentamicin 10
Wk 12 · 2026-03-04
Zone: 28 Range: 19–26
Disc placed too close to edge of plate. Zone asymmetric. Re-tested with new disc from same lot — result 22 (within range). Training reminder issued to reader.
OOR P. aeruginosa 27853 · Piperacillin-Taz. 36
Wk 10 · 2026-02-18
Zone: 29 Range: 21–27
New lot of discs opened mid-week. Repeat with original lot — result 25. New lot quarantined pending supplier investigation.

Audit Log

Every action in ASTRA is recorded automatically. The audit log captures logins, data saves, corrective actions, settings changes, and EUCAST version updates — each with a timestamp, user, and full context.

  • Timestamped, user-attributed entries for every action
  • Filter by category — authentication, data, settings, EUCAST
  • Deactivated organisms and antibiotics preserved, never deleted
  • Historical reference ranges retained when versions change
astra-qc.co.uk — Audit Log
Audit Log
All Auth Data Settings
Time User Type Action
08:42:15S. ClarkeauthLogin
08:47:31S. ClarkedataQC Data Saved · E. coli 25922 · Wk 12
08:47:31S. ClarkedataCorrective Action · Gentamicin 10 · 28
09:12:04J. MorgansettingsOrganism Added · H. influenzae 49247
14:20:58J. MorganeucastEUCAST Version Changed · v16.0

Ready to Modernise Your Lab QC?

Replace spreadsheets with a purpose-built platform. Get audit-ready compliance, automatic trend analysis, and Westgard rule detection — out of the box.

Request a Demo

Interested in ASTRA for your laboratory? Fill in the form and we'll arrange a personalised demonstration of the platform.

Free personalised walkthrough
See how ASTRA fits your lab's QC workflow
No obligation — just a conversation